Application: Mountain water measurement tunnel construction

Flow measurements for media containing solids with large measuring ranges, optionally extendable with sensors for the determination of further medium properties. Our engineers support you from the evaluation of the suitable measuring point to installation and commissioning. We also provide solutions for the transmission, recording and evaluation of the measured data.

Verify measurement data through a check
We offer a wide range of services for the carefree operation of your drinking water network. If you suspect that something in the network system is no longer working properly, or simply want a general check of the installations, STEBATEC has just the right offer for you.
Highly Precise Ultrasonic transit-time difference flow measurement for wastewater, raw wastewater and rainwater
Highly precise flow value acquisition. The LDM is a calibrated measuring device for backflow-free flow measurement of waste water in open channels or free flowing lines. 10 flow velocity measuring sections distributed over the entire cross section provide most accurate flow values when the sensor is partially or fully filled. The level measurement is integrated in the device housing.
Temporary use of the proven MID for full filling to collect high-precision measurement data.
Waste water and external water flow measurement Measurements are performed with a high-precision, portable MID flowmeter mechanically protected by a plastic layer, which is normally installed in existing shafts and ducts without structural modifications. A bypass cushion completely seals the channel cross section and guides the entire water quantity completely through the measuring system.
Special solutions for measuring wastewater, raw wastewater and rainwater under the most difficult conditions.
When the impossible becomes possible. High flow velocities, steep gradients, tight spaces, large measuring range. The more difficult the measuring task, the more suitable is the stationary flow measurement, which can often be retrofitted in existing structures and shafts.
Ultrasonic transit time difference measurement with dry weather gutter
The TF Stationary Flow Measurement is a calibrated measuring channel for backflow-free flow measurement of wastewater, raw wastewater and rainwater in open channels or open channels.
Non-intrusive ultrasonic flow measurement for closed and fully filled pipelines.
Flow measurement on the outer wall of the pipe. With a flowmeter with clamp-on transducers it is possible to measure the flow in pipes simply from the outside. The transducers are installed on the pipeline with little technical effort and without process interruption. Rotationally symmetric flow profiles can be measured with only one acoustic section; non-symmetric ones require the use of several sections.